APPENDIX E
Advanced Breakout Board
E-6
SELECTING ADVANCED BRAKE CONTROLLER BRAKING CONFIGURATION
Use the Braking Configuration area of the Advanced Brake Controller screen to select
the Speed Balance and/or Gauges Tied option.
SETTING THE SPEED BALANCE
Using Speed Balance is the default setting. Speed Balance uses braking to minimize or
eliminate any difference in speed between the front and rear dyno when speeding up
or slowing down.
To use Speed Balance, make sure that the box to the left of Speed Balance is
checked.
When using Speed Balance, the Gauges Ties selection is grayed-out. Gauges
must be tied when using Speed Balance.
The Proportional, Integral, and Differential values (PID settings) are
coefficients used in the calculations for Speed Balance. Each speed channel
has a set of PID values. The PID settings are preset to the values shown in
Figure E-4.
The default values work for most dyno configurations and all-wheel drive
systems. Changing these values may result in damage to the vehicle.
Figure E-4: The Advanced Brake Controller Screen
speed balance
selected
speed channel
PID settings are critical
to braking control. Do
not change these
values without
checking with
Technical Support